Single-gas Detectors
  Multi-gas Detectors
  Fixed Gas transmitters
  FG10S
  FG10
  Fixed Controllers
  Gas Sensor
Home > Products

l The instrument can be equipped with dozens of kinds of sensors such as electrochemical, catalytic, non-dispersive infrared (NDIR) and photo-ionization detector (PID) sensors in order to meet users’ different demands;

l The instrument can not only display the concentration of a dangerous gas in real time but also calculate the TWA and STEL values of a toxic gas and display the results on the LCD as per corresponding instructions;

l The instrument possesses analog, digital and on/off signal outputs simultaneously;

l The ultra-large LCD screen is equipped with ultra-bright backlight, convenient for reading;

l  Its Protection Classification can exceed IP66;

l One key recovery function enables you to not worry about wrong operations.

Part No.

90005000-G1

Gas Detected

Sulfur dioxide, SO2

Sampling Method

Diffusion

Gas Sensor

Triple-electrode electrochemical sensor

Measure Range

0100ppm    

Resolution

0.1ppm

Response Time

Less than 30 seconds

Power Supply

Voltage: (15~30)VDC, electricity: 50mA

Electric Interface

3/4’’NPT

Display

Displayed with large screen LCD

Alarm method

3-LED lights alarms

Signal Output

Analog signal(4~20)mA, loading resistance: 500Ω

Digital signal RS485 ModBus RTU communication protocol

On/off  signal: 3 relays

Wiring Method

Triple wire system; Power, GND, Signal

Protection Classification

IP66

Environment Temperature

-20~ 50

Environment Humidity

15%~ 95% relative humidity (standard)

Explosion-Proof

Ex d IIC T6

Size

209mm*133mm*110mm (length*width*height)

Weight

2.2 kg

Materials of the cases

Casting aluminum and stainless steel

Sulfur Dioxide - SO2 

 

Hazard:                       Flammable       Will not explode

Classification:           Health                Extremely toxic 

Oxidizing agent

Synonyms:                Sulfurous acid anhydride, sulfurous oxide, and sulfur oxide

Exposure limits:       (OSHA) PEL\TWA: 5 ppm

                                    (ACGIH) STEL: 0.25 ppm/ 15 min

                                    (OSHA) IDLH: 100 ppm / 30 min  

Industries:                 Pulp and paper mills, and coal fired generating stations 

 

Sulfur dioxide is a colorless gas with a characteristic, irritating, pungent odor. Sulfur dioxide is released when compounds containing sulfur, such as fossil fuels like coal are burned.

 

Sulfur dioxide is a highly toxic gas which poisons its victims via inhalation through the lungs. SO2 combines with water to form sulfuric acid (H2SO4). It is for this reason sulfur dioxide can burn the respiratory tract upon inhalation. High doses of sulfur dioxide can cause death quite rapidly.

 

Effects of Various SO2 Levels  

Sulfur OxideLevel in PPM         Resulting Conditions on Humans

.3-1                                     Sulfur Dioxide initially detected by taste

5                                          Permissible Exposure Level (OSHA)

3                                          Odor becomes easily detected

6-12                                    Irritation of the nose and throat

20                                        Irritation of the eyes

50-100                               Maximum exposure for a 30 minute period

400-500                             Dangerous concentration can cause edema of the lungs and glottis and death from prolonged exposure

   
Annix GmbH
Oberer Tiegel 4A 97249 Eisingen
Germany
Tel:049 9306 576023
沪ICP备14038069号
Home | Company Profile | Products | News | Information Center | Contact Us