Single-gas Detectors
  Multi-gas Detectors
  Fixed Gas transmitters
  FG10S
  FG10
  Fixed Controllers
  Gas Sensor
Home > Products

l The instrument can be equipped with dozens of kinds of sensors such as electrochemical, catalytic, non-dispersive infrared (NDIR) and photo-ionization detector (PID) sensors in order to meet users’ different demands;

l The instrument can not only display the concentration of a dangerous gas in real time but also calculate the TWA and STEL values of a toxic gas and display the results on the LCD as per corresponding instructions;

l The instrument possesses analog, digital and on/off signal outputs simultaneously;

l The ultra-large LCD screen is equipped with ultra-bright backlight, convenient for reading;

l  Its Protection Classification can exceed IP66;

l One key recovery function enables you to not worry about wrong operations.

Part No.

90005000-C1

Gas Detected

Oxygen, O2

Sampling Method

Diffusion

Gas Sensor

Electrochemical sensor

Measure Range

030%Vol.    

Resolution

0.1%Vol.

Response Time

Less than 30 seconds

Power Supply

Voltage: (15~30)VDC, electricity: 50mA

Electric Interface

3/4’’NPT

Display

Displayed with large screen LCD

Alarm method

3-LED lights alarms

Signal Output

Analog signal(4~20)mA, loading resistance: 500Ω

Digital signal RS485 ModBus RTU communication protocol

On/off  signal: 3 relays

Wiring Method

Triple wire system; Power, GND, Signal

Protection Classification

IP66

Environment Temperature

-20~ 50

Environment Humidity

15%~ 95% relative humidity (standard)

Explosion-Proof

Ex d IIC T6

Size

209mm*133mm*110mm (length*width*height)

Weight

2.2 kg

Materials of the cases

Casting aluminum and stainless steel

Effects of Various O2 Levels

 

Concentration Of Oxygen Resulting Conditions on Humans

23.5%        Volume Maximum "Safe Level"; OSHA

21%           Oxygen Concentration of AIR (20.954)

19.5%       Minimum "Safe Level"; OSHA, NIOSH

17%           Impairment of judgment starts to be evident

16%           First signs of anoxia appears 

16-12%     Breathing and pulse rate increases, muscular co-ordination is slightly impaired

14-10%     Consciousness continuous; emotional upsets, abnormal fatigue upon exertion, disturbed respiration

10-6%       Nausea and vomiting, inability to move freely and loss of consciousness may occur

 <6%         Convulsive movements and gasping respiration occurs; respiration stops and a few minutes later heart action ceases

   
Annix GmbH
Oberer Tiegel 4A 97249 Eisingen
Germany
Tel:049 9306 576023
沪ICP备14038069号